Skip to main content
Standards

Compliance, stated plainly

Every standard is shown with its real scope and status — certified, in progress, or used as a development basis.

Standards and compliance

An industrialisation path with auditable criteria

In ESC and safety-system programs, alignment with ECE, ISO 26262, ISO 9001, IATF 16949 and OEM requirements is mandatory.

  • ISO 26262Functional safety
    Scope

    Safety-critical systems including ESC, EPS, EHB, SCU and BMS

    Systems are developed against ISO 26262 requirements; this is not a certification claim.

    Designed to standard
  • ISO 9001 · IATF 16949Organisational quality
    Scope

    Automotive supply chain

    ISO 9001 is established and the IATF 16949 implementation path is under way.

    Certification in progress
  • ECE R10Electromagnetic compatibility
    Scope

    EMC/EMI of vehicle electronic systems

    Systems are designed and tested against ECE R10 requirements.

    Designed to standard
  • ECE R13H · ECE R140Braking and stability control
    Scope

    Vehicle braking and stability control requirements

    ESC and braking systems are developed and validated against ECE R13H and ECE R140.

    Designed to standard
  • EOL · TraceabilityProduction and traceability
    Scope

    Production line and safety-critical products

    Traceability, EOL, production data logging and 100% in-line control of safety-critical products.

    Implemented

Industrialisation approach

Every program is run from AP/VP/EP through to SOP with technical documentation, a requirement matrix, DVP, test reports, software and calibration versions, BOM, quality control and an EOL process.

Program phases
  1. AP

    Advanced prototype — concept and architecture proof

  2. VP

    Validation prototype — in-vehicle performance confirmation

  3. EP

    Engineering prototype — production preparation

  4. SOP

    Start of production with quality control and EOL

Deliverable documents
  • System architecture description and block diagram
  • CAN/CAN FD communication matrix and DTC list
  • Calibration file and software version
  • Test plan, DVP and validation report
  • Installation, commissioning, service and diagnostics guide
  • EOL plan and production acceptance criteria
  • Quality assurance report and risk analysis